Abstract
Electric utilities adapt to changing loads on their grids that can vary within a day, from day to day, and by location.
To some extent, utilities can predict the magnitude and location of electricity demand in advance, and from knowledge of available power supplies and transmission costs, develop hourly prices for the delivery of electricity to specific locations.
Such hourly price lists are often shared across national regions and are made available 24 h in advance.
A new day ahead market (DAM) greenhouse light control algorithm was developed that predicted the amount of natural (sun) light available for a particular day and then estimated the number of hours of supplemental lighting required to reach a daily light integral (DLI) target.
The control algorithm then sought to minimize the cost of electricity by finding the least expensive hours of the day to use supplemental lighting.
Because many greenhouse operations are still equipped with high pressure sodium (HPS) fixtures to provide their supplemental light, a further constraint on the algorithm was to minimize the number of daily on/off cycles to two because HPS bulbs require a relatively long warm up period and suffer from repeated on/off cycling.
Through simulations with historic weather and DAM pricing data for select New York state locations using supplemental HPS lighting, the algorithm was able to reduce electricity cost for supplemental lighting by up to 80% when compared to another DLI controller operating under a simpler on-peak and off-peak rate schedule.
The DAM algorithm also showed that higher intensity supplemental light can reduce operating costs by reducing the hours of lighting to reach target DLI and shifting those hours to lower cost hours of the day.

Publication
Authors
T. Shelford, A.J. Both, N.S. Mattson
Keywords
energy consumption, supplemental-lighting, lighting control
Full text
Online Articles (57)
F. Montefiori | G. Pennisi | A. Pistillo | F. Orsini | S. Nicola | J.A. Fèrnandez | A. Crepaldi | G. Gianquinto
I. Paucek | G. Pennisi | A. Pistillo | E. Appolloni | A. Crepaldi | B. Calegari | F. Spinelli | A. Cellini | G. Gianquinto | F. Orsini
W. Vanlommel | J. Moelants | L. Bosmans | R. Vanderbruggen | T. Van Delm | L. Wittemans | J. Vermeiren | K. Steppe
M.W. van Iersel | G. Weaver | R. Legendre | C. Kim
M.T. Naznin | M. Lefsrud | V. Gravel | X.Md. Obyedul Kalam Azad | B. Waechter Alsanius
V. Vaštakaitė-Kairienė | A. Brazaitytė | G. Samuolienė | A. Viršilė | J. Miliauskienė | J. Jankauskienė | A. Novičkovas | P. Duchovskis
A. Viršilė | G. Balaika | G. Samuolienė | A. Brazaitytė | J. Jankauskienė | J. Miliauskienė | K. Laužikė | P.H. Haimi
Ngo-Viet Duc | M. Chowdhury | M. Ali | Sang-Un Park | Yong-Joo Kim | Sun-Ok Chung
V. Vaštakaitė-Kairienė | A. Brazaitytė | J. Miliauskienė | K. Laužikė | R. Sutulienė | P. Duchovskis | G. Samuolienė
G. Ma | L.C. Zhang | M. Yahata | K. Yamawaki | T. Shimada | H. Fujii | T. Endo | M. Kato
I. Zauli | E. Appolloni | L. Carotti | I. Paucek | S. Quaini | G. Pennisi | F. Orsini | G. Gianquinto
A. Pistillo | G. Pennisi | A. Crepaldi | M.E. Giorgioni | A. Minelli | F. Orsini | G. Gianquinto
S. Toda | T. Higuchi | T. Sakamoto | T. Kanoh | N. Fujiuchi | H. Nishina | K. Takayama
N. Kuźma | J. Rabiza-Świder | E. Skutnik | A. Jędrzejuk
F.J. López | M.T. Soriano | F. Kempkes | E. Baeza | J. Janse
N. García Victoria | K. Weerheim | F. Kempkes | J. Steenhuizen | M. De Groot
N.S. Mattson | J.A. Allred | D. de Villiers | T. Shelford | K. Harbick
F. Bantis | A. Koukounaras | A. Siomos | K. Radoglou | C. Dangitsis | T. Koufakis
G. Mupambi | T. Schmidt | N. Valverdi | H. Camargo-Alvarez | M. Reid | L. Kalcsits